You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
Looking for Z-Box Hub Support? Please click here to access the Z-Box Hub Support Portal.
announcement close button
ZEN26 S2 On/Off Switch VER. 3.02 Advanced Settings
print icon

Here is a full list of advanced settings (parameters) for ZEN26 On/Off Switch VER. 3.02 firmware:

On/Off Paddle Orientation

Parameter 1: Choose if you want the upper paddle to turn the light on or turn the light off when tapped.

Values: 0 – Upper paddle turns the light on, lower paddle turns it off (default); 1 – Upper paddle turns the light off, lower paddle turns it on; 2 – Any paddle turns light on/off.

Size: 1 byte dec

LED Indicator Control

Parameter 2: Choose if you want the LED indicator to turn on when the switch (light) is on or off, or if you want it to remain on or off at all times.

Values: 0 – LED indicator is on when switch is off, LED indicator is off when switch is on (default); 1 – LED indicator is on when switch is on, LED indicator is off when switch is off; 2 – LED indicator is always OFF; 3 – LED indicator is always ON. NOTE: tap the upper paddle 6 times quickly to change this mode.

Size: 1 byte dec

Auto Turn-Off Timer

Parameter 3: Use this parameter to enable or disable the auto turn-off timer function.

Values: 0 – timer disabled (default); 1 – timer enabled.

Size: 1 byte dec

 

Parameter 4: Use this parameter to set the time after which you want the switch to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes.

Values: 1 – 65535 (minutes). Default: 60.

Size: 4 byte dec

Auto Turn-On Timer

Parameter 5: Use this parameter to enable or disable the auto turn-on timer function.

Values: 0 – timer disabled (default); 1 – timer enabled.

Size: 1 byte dec

 

Parameter 6: Use this parameter to set the time after which you want the switch to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes.

Values: 1 – 65535 (minutes). Default: 60.

Size: 4 byte dec

Association Reports

Parameter 7: Choose which physical and Z-Wave triggers should prompt the switch to send a status change report to associated devices.

Values: 0 – none; 1 – physical tap on ZEN26 only; 2 – physical tap on connected 3-way switch only; 3 – physical tap on ZEN26 or connected 3-way switch; 4 – Z-Wave command from hub; 5 – physical tap on ZEN26 or Z-Wave command from hub; 6 – physical tap on connected 3-way switch or Z-Wave command from hub; 7 – physical tap on ZEN26 / connected 3-way switch or Z-Wave command from hub; 8 – timer only; 9 – physical tap on ZEN26 or timer; 10 – physical tap on connected 3-way switch or timer; 11 – physical tap on ZEN26 / connected 3-way switch or timer; 12 – Z-Wave command from hub or timer; 13 – physical tap on ZEN26, Z-Wave command from hub, or timer; 14 – physical tap on ZEN26 / connected 3-way switch, Z-Wave command from hub, or timer; 15 – all of the above. Default: 15.

Size: 1 byte dec

On Off Status After Power Failure

Parameter 8: Set the on off status for the switch after power failure.

Values: 0 – forced to OFF (regardless of state prior to power outage); 1 – forced to ON (regardless of state prior to power outage); 2 – remembers and restores on/off status after power failure (default)

Size: 1 byte dec

Enable/Disable Scene Control

Parameter 10: Enable or disable scene control functionality for quick double tap triggers.

Values: 0 – scene control disabled (default). 1 – scene control enabled.

Size: 1 byte dec

Smart Bulb Mode: Enable/Disable Paddle / Z-Wave Control

Parameter 11: Enable or disable physical on/off control. If enabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through paddles.

Values: 0 – physical paddle control disabled. 1 – physical paddle control enabled (default). 2 – physical AND Z-Wave control disabled. NOTE: tap the upper paddle 10 times quickly to change this mode.

Size: 1 byte dec

 

Parameter 13: Set reporting behavior for disabled physical control.

Values: 0 – switch reports on/off status and change LED indicator state even if physical and Z-Wave control is disabled (default). 1 – switch doesn't report on/off status or change LED indicator state when physical (and Z-Wave) control is disabled.

Size: 1 byte dec

 

MANUAL CONTROL

Upper Paddle: 

1 x tap: load on; Scene 2, attribute 00 (button 1)

2 x tap: Scene 2, attribute 03 (button 3)

3 x tap: enter inclusion (pairing) mode; Scene 2, attribute 04 (button 5)

4 x tap: Scene 2, attribute 05 (button 7)

5 x tap: Scene 2, attribute 06 (button 9)

6 x tap: change LED indicator mode (see parameter 2)

held: Scene 2, attribute 01

released: Scene 2, attribute 02

tap-tap-tap-tap-and-hold: change physical / Z-Wave control mode (see parameter 11)

tap-tap-tap-and-hold: factory reset

 

Lower Paddle: 

1 x tap: load off; Scene 1, attribute 00 (button 2)

2 x tap: Scene 1, attribute 03 (button 4)

3 x tap: enter exclusion (unpairing) mode; Scene 1, attribute 04 (button 6)

4 x tap: Scene 1, attribute 05 (button 8)

5 x tap: Scene 1, attribute 06 (button 10)

held: Scene 1, attribute 01

released: Scene 1, attribute 02

tap-tap-tap-and-hold: factory reset

 

How to Access Advanced Settings:

SmartThings

Hubitat

Vera

Home Assistant

 

All ZEN26 switches can be updated via OTA firmware updates, here is how to do that.  You'll be able to access all firmware files here once you register your product and create an account in our support portal. Questions? Feel free reach out to our customer service, we reply 7 days a week!

Feedback
2 out of 5 found this helpful

Have you tried our virtual assistant chatbot? This AI tool can help you find answers from thousands of articles in our Knowledge Base quickly. Find it in the bottom righthand corner of the page.

Need more help? Our friendly team is ready to help you with any questions or concerns you may have about Zooz devices. Click here to submit a support ticket.

Are your devices registered? Extended warranty and firmware access is available for registered Zooz customers. Click here to submit your registration form.

Find the latest Zooz devices and great Z-Wave deals at The Smartest House.
 
scroll to top icon