Here is a full list of advanced settings (parameters) for the ZEN15 Power Switch:
Some parameters were added in later firmware updates so please make sure you're on the latest firmware to have all of the settings below available. You can view the change log for the ZEN15 here.
Overload Protection
Parameter 20:
500 series: Overload protection turns the ZEN15 off once power exceeds 16.5A when enabled. We DO NOT recommend disabling the setting.
Values: 0 – Disabled; 1 – Enabled. Default: 1
Size: 1 byte dec
Overload Protection Delay
Parameter 20:
800 series FW 2.10 and up: Decide when overload protection kicks in. If power draw exceeds 16.5 A for x amount of seconds, the plug will automatically turn off.
Values: 2 - 5 (seconds). Default: 2
Size: 1 byte dec
On/Off Status After Power Failure
Parameter 21: Choose the recovery state for your Power Switch if power outage occurs.
Values: 0 – remembers and restores status; 1 – always on once restored; 2 – always off once restored. Default: 0.
Size: 1 byte dec
On/Off Status Reports
Parameter 24: Choose when you want the device to send on/off reports to the hub and associated devices.
Values: 0 – no reports; 1 – reports on/off if status changed manually or via Z-Wave; 2 – reports on/off only if status changed manually from the button. Default: 1.
LED Indicator Behavior
Parameter 27: Decide how the LED indicator displays power consumption on the Power Switch and when it’s on or off.
Values: 0 – LED always on with power use display; 1 – LED on when plug on (with power use display), LED off when plug off; 2 – LED on with power use for 5 seconds after status change (off otherwise); 3 – LED always off. Default: 1.
Size: 1 byte dec
Find out how to reach LED indicator colors and how to enable the range test tool in the manual.
Disable Manual Control
Parameter 30: Disable or enable manual control (turning the Power Switch on and off using the physical button).
Values: 0 – manual control disabled; 1 – manual control enabled. Default: 1.
Size: 1 byte dec
Disable Z-Wave ON Commands
Parameter 31: Ignore Z-Wave ON commands sent from the hub to the Power Switch. Turn it ON only from the button. You can still turn the plug OFF via Z-Wave.
Values: 0 – Z-Wave on commands disabled; 1 – Z-Wave on commands enabled. Default: 1.
Size: 1 byte dec
Disable Z-Wave OFF Commands
Parameter 32: Ignore Z-Wave OFF commands sent from the hub to the Power Switch. Turn it OFF only from the button. You can still turn the plug ON via Z-Wave.
Values: 0 – Z-Wave off commands disabled; 1 – Z-Wave off commands enabled. Default: 1.
Size: 1 byte dec
Auto-on Timer
Parameter 33: Auto-on timer will automatically turn the Power Switch on after x minutes once it has been turned off.
Values: 0 – timer disabled; 1-99 (minutes). Default: 0.
Size: 1 byte dec
Auto-off Timer
Parameter 34: Auto-off timer will automatically turn the Power Switch off after x minutes once it has been turned on.
Values: 0 – timer disabled; 1-99 (minutes). Default: 0.
Size: 1 byte dec
Turn On Delay After Power Outage
Parameter 35: Disable or set the delay for the automatic turn on after the plug was turned off due to power outage.
Values: 0 – no delay; 1~65535 (seconds). Default: 0.
Size: 2 byte dec
Auto Turn On After Overload - 800 series only
Parameter 36: Disable or set the delay for the automatic turn on after the plug was turned off due to overload protection.
Values: 0 – auto-turn on disabled; 10~65535 (seconds). Default: 0.
Size: 2 byte dec
Watt Report Threshold
Parameter 151: Choose when the plug will report Watts to your hub. Value 1 = 1 Watt change.
Values: 0 – trigger disabled; 1 – 65535. Default: 50.
Size: 2 byte dec
Watt Report % Threshold
Parameter 152: Choose when the plug will report Watts to your hub based on % change. Value 10 = 10 % change.
Values: 0 – trigger disabled; 1 – 99 (%). Default: 10.
Size: 1 byte dec
Watt Report Frequency
Parameter 171: Decide how often the plug will report Watt data to the hub (in second intervals).
Values: 0 – reports disabled; 5 – 2678400 (seconds). Default: 300.
*Firmware 2.30 and below: default value is 30. Once updated to 2.30, devices using the previous default value (30 seconds) will be automatically updated to 300 seconds. Devices with a custom value configured will remain unchanged.
Size: 4 byte dec
kWh Report Frequency
Parameter 172: Decide how often the plug will report kWh data to the hub (in second intervals).
Values: 0 – reports disabled; 5 – 2678400 (seconds). Default: 300.
Size: 4 byte dec
Volt Report Frequency
Parameter 173: Decide how often the plug will report Volt data to the hub (in second intervals).
Values: 0 – reports disabled; 5 – 2678400 (seconds). Default: 300.
Size: 4 byte dec
Amp Report Frequency
Parameter 174: Decide how often the plug will report Amp data to the hub (in second intervals).
Values: 0 – reports disabled; 5 – 2678400 (seconds) Default: 300.
Size: 4 byte dec
Volt Report Threshold - 800 series only
Parameter 175: Choose when the plug will report Volts to your hub. Value 1 = 1 V and value 10 = 10 V change.
Values: 0 – trigger disabled; 1 – 255 (Volts) Default: 10.
Size: 1 byte dec
Amp Report Threshold - 800 Series Only
Parameter 176: Choose when the plug will report Amps to your hub. Value 1 = 0.001 A and value 1000 = 1 A change.
Values: 0 – trigger disabled; 1 – 65535 (1 = 0.001A and 1000 = 1A). Default: 1000.
Size: 2 byte dec
How to Access the Advanced Settings
How to Access the Advanced Settings for the ZEN15 on Home Assistant
How to Access the Advanced Settings for the ZEN15 on HomeSeer
How to Access the Advanced Settings for the ZEN15 on Hubitat
How to Access the Advanced Settings for the ZEN15 on SmartThings
How to Access the Advanced Settings for the ZEN15 on Z-Box
All ZEN15 Power Switches can be updated via OTA firmware updates, here is how to do that. You can access all firmware files here. Please make sure you verify your hardware and firmware version to ensure you apply the correct update. Questions? Just reach out to our tech support team.