Here is a log of upgrades and improvements we made to the ZEN71 On/Off Switch 700 model so far.
VER. 1.0 (released 12/2020)
Original release.
Hardware:
- Based on the ZEN21 500 series version with a direct 3-way solution
- 700 Series Z-Wave chip
- Just 1.16" deep
- No heatsink tabs
- Multicolor LED indicator
- Replaceable paddles (color kits available here)
Firmware: 1.01
-
SmartStart and S2 authenticated security
-
Built-in range test tool
-
Built-in signal repeater
-
Smart bulb mode
-
Scene control command class (multi-tap triggers)
VER. 10.0 (released 6/2021)
Firmware: 10.0
- Remove manual operation delay with scene control disabled
- Fixed smart bulb behavior after a power outage: the actual status of the relay and the reported status of the relay are both restored correctly now
- Added the ability to disable programming function from the paddles (parameter 17, see all of the settings here)
VER. 10.10 (released 09/2022 as OTA)
Firmware: 10.10
- Fixed S2 inclusion issue related to data packet size for advanced setting labels which affected selected hubs and scenarios
VER. 10.20 (released 05/2023 as OTA)
Firmware: 10.20
- Fixed central scene bug for control of its own load in smart bulb mode
- Added parameter 7 to choose Direct Association reports sent to devices associated with the Z-Wave. See all settings here.
- Added parameter 18 to enable scene control from the momentary switch in a 3-way. See all settings here.
- Added parameter 19 to disable LED blinking when a setting is changed. See all settings here.
- Changed the manual operation for disabling the relay (smart bulb mode): Hold the UPPER paddle for 10 seconds until the LED indicator starts blinking, then within 2 seconds, tap the upper paddle 5 times quickly to change this mode. The LED indicator will stay solid green for 3 seconds to confirm the change.
- Improved the factory reset procedure: The switch will not lock up if the factory reset is not successful in certain scenarios.
VER. 10.30 (released 09/2024 as OTA)
Firmware: 10.30
- Improved Direct Association Group 2 for the basic set on/off functionality.
VER. 2.0 (released 06/2022)
Hardware: 2.0
- Updated the Voltage regulator to improve surge protection
Firmware: 2.0
- Based on 10.00 firmware (see above)
VER. 2.10 (released 09/2022 as OTA)
Firmware: 2.10
- Based on 10.10 OTA changes (see above)
VER. 2.20 (released 05/2023 as OTA)
Firmware: 2.20
- Based on 10.20 OTA changes (see above)
VER. 2.30 (released 09/2024 as OTA)
Firmware: 2.30
- Based on 10.30 OTA changes (see above)
VER. 800LR (released 05/2023)
Hardware: 3.0
- 800 Series Z-Wave chip
Firmware: 3.10
- Based on 10.20 firmware (see above)
- Long Range ready
Firmware: 3.20 (released 07/2023 as OTA)
- Addressed occasional performance issues for switches connected to fans.
- Addressed issues with the switch occasionally showing offline or becoming unresponsive on select platforms.
Firmware: 3.30 (released 09/2023 as OTA)
- Improved Direct Association Group 2 for the basic set on/off functionality.
Firmware: 3.40 (released 09/2024 as OTA)
- Fixed the Range Test Tool feature
Firmware: 3.50 (released 02/2025 as OTA)
- Updated parameter names and short descriptions in the Configuration Command Class to match the Advanced Setting Article
Firmware: 3.60 (released 06/2025 as OTA)
- Added new parameters: 20 – Scene Control Multi-Tap, 21 – LED Indicator Multi-Color. You can view all available settings here.
Firmware: 3.70 (released 07/2025 as OTA)
- Optimized Z-Wave reporting behavior: when Basic Set and Binary Set commands are sent from the Z-Wave controller (Lifeline), the device will no longer send redundant report or notification commands back to the controller.
VER. 4.xx 800LR (released 12/2025)
Hardware: 4
- Redesigned the decora paddle. Please note that VER 4.0 (hardware 4) decora paddles cannot be installed on ZEN71 with firmware 3.xx and lower, and older decora paddles cannot be installed on ZEN71 with firmware 4.xx. For more information on identifying your version, please see the ZEN71 FAQ's.
-
Redesigned PCB layout with separation into two boards: RF board and Power board
-
Updated operating voltage range to 120–277 V
-
Replaced F1 fuse with a self-resetting (self-recovery) fuse
Firmware: 4.00
- Based on 3.70 firmware