ZEN71 On/Off Switch Advanced Settings
print icon

Here is a full list of advanced settings (parameters) for ZEN71 On/Off Switch:

Some parameters were added in later firmware updates so please make sure you're on the latest firmware to have all of the settings below available. You can view the change log for the ZEN71 here.

On/Off Paddle Orientation

Parameter 1: Choose if you want the upper paddle to turn the light on or turn the light off when tapped.

Values: 0 – Upper paddle turns the light on, lower paddle turns it off (default); 1 – Upper paddle turns the light off, lower paddle turns it on; 2 – Any paddle turns light on/off.

Size: 1 byte dec

LED Indicator Control

Parameter 2: Choose if you want the LED indicator to turn on when the switch (light) is on or off, or if you want it to remain on or off at all times.

Values: 0 – LED indicator is on when switch is off, LED indicator is off when switch is on (default); 1 – LED indicator is on when switch is on, LED indicator is off when switch is off; 2 – LED indicator is always OFF; 3 – LED indicator is always ON. NOTE: tap the upper paddle 6 times quickly to change this mode.

Size: 1 byte dec

 

Parameter 14: Choose the color of the LED indicator.

Values: 0 – white; 1 – blue (default); 2 – green; 3 – red.

Size: 1 byte dec

 

Parameter 15: Choose the LED indicator's brightness level.

Values: 0 – bright (100%); 1 – medium (60%); 2 – low (30%). Default: 1.

Size: 1 byte dec

 

Parameter 19: Enable / disable LED indicator for setting changes. Choose if you want the LED indicators to flash whenever a parameter (settings) is adjusted on the device to confirm the change. Disable this feature if you're using the LED indicators in automations.

Values: 0 – LED indicators flash to confirm a setting change (default); 1 - LED indicators don't flash if a setting is changed. Default: 0.

Size: 1 byte dec

Auto Turn-Off Timer

Parameter 3: Use this parameter to enable or disable the auto turn-off timer function (the time after which you want the switch to automatically turn off once it has been turned on).

Values: 0 – timer disabled (default); 1 – 65535 (minutes).

Size: 4 byte dec

 

Auto Turn-On Timer

Parameter 5: Use this parameter to enable or disable the auto turn-on timer function (the time after which you want the switch to automatically turn on once it has been turned off).

Values: 0 – timer disabled (default); 1 – 65535 (minutes).

Size: 4 byte dec

On Off Status After Power Failure

Parameter 8: Set the on off status for the switch after power failure.

Values: 0 – forced to OFF (regardless of state prior to power outage); 1 – forced to ON (regardless of state prior to power outage); 2 – remembers and restores on/off status after power failure (default)

Size: 1 byte dec

Enable/Disable Scene Control

Parameter 9: Enable or disable scene control functionality for quick double tap triggers.

Values: 0 – scene control disabled (default). 1 – scene control enabled.

Size: 1 byte dec

 

Parameter 18: Enable scene control functionality from the momentary switch in a 3-way installation.

Values: 0 – scene control disabled commands from the remote 3-way switch disabled (default). 1 – scene control commands from the remote 3-way switch enabled. Default: 0

Size: 1 byte dec

Smart Bulb Mode: Enable/Disable Paddle / Z-Wave Control

Parameter 11: Enable or disable local on/off control. If enabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through paddles.

Values: 0 – physical paddle control disabled. 1 – physical paddle control enabled (default). 2 – physical paddle and Z-Wave control disabled. 

NOTE: hold the lower paddle for 10 seconds until the LED indicator starts blinking, then within 2 seconds, tap the upper paddle 5 times quickly to change this mode. The LED indicator will stay solid green for 3 seconds to confirm the change.

FOR FIRMWARE 10.20, 2.20 AND 3.10 (800LR) (or higher)Hold the UPPER paddle for 10 seconds until the LED indicator starts blinking, then within 2 seconds, tap the upper paddle 5 times quickly to change this mode. The LED indicator will stay solid green for 3 seconds to confirm the change.

Size: 1 byte dec

 

Parameter 13: Set reporting behavior for disabled physical control.

Values: 0 – switch reports on/off status and change LED indicator state even if physical and Z-Wave control is disabled (default). 1 – switch doesn't report on/off status or change LED indicator state when physical (and Z-Wave) control is disabled.

Size: 1 byte dec

3-Way Switch Type

Parameter 12: Choose the type of 3-way switch you want to use with this switch in a 3-way set-up.

Values: 0 – regular mechanical 3-way on/off switch, use the connected 3-way switch to turn the light on or off (default); 1 – momentary switch, click once to change status (light on or off)

Size: 1 byte dec

Association Reports

Parameter 7: Choose which physical and Z-Wave triggers should prompt the switch to send a status change report to the associated devices.

Values: 0 – none; 1 – physical tap on ZEN71 only; 2 - physical tap on connected 3-way switch only; 3 - physical tap on ZEN71 or connected 3-way switch; 4 - Z-Wave command from hub; 5 - physical tap on ZEN71 or Z-Wave command from hub; 6 - physical tap on connected 3-way switch or Z-Wave command from hub; 7 - physical tap on ZEN71 / connected 3-way switch or Z-Wave command from hub; 8 - timer only; 9 - physical tap on ZEN71 or timer; 10 - physical tap on connected 3-way switch or timer; 11 - physical tap on ZEN71 / connected 3-way switch or timer; 12 - Z-Wave command from hub or timer; 13 - physical tap on ZEN71, Z-Wave command from hub, or timer; 14 - physical tap on ZEN71 / connected 3-way switch, Z-Wave command from hub, or timer; 15 - all of the above. Default: 15. 

Size: 1 byte dec

 

Parameter 16: Choose how the switch reports its status back to the hub.

Values: 0 – Binary switch report for Z-Wave control, basic set report for paddle control; 1 – binary switch report for both Z-Wave and paddle control (default)

Size: 1 byte dec

Enable/Disable Programming on the Paddles

Parameter 17: Enable or disable programming functionality on the switch paddles. If this setting is disabled, then inclusion, exclusion, smart bulb mode no longer work when switch paddles are activated (factory reset and scene control will still work) - that means you can now use triple-tap triggers on the switch for scenes and remote control of other devices.

Values: 0 – programming enabled (default). 1 – programming disabled.

Size: 1 byte dec

MANUAL CONTROL

Upper Paddle: 

1 x tap: load on; Scene 1, attribute 00

2 x tap: Scene 1, attribute 03

3 x tap: enter inclusion (pairing) mode (only if the switch is not included to the hub); Scene 1, attribute 04

4 x tap: Scene 1, attribute 05

5 x tap: Scene 1, attribute 06

6 x tap: change LED indicator mode (see parameter 2)

held: Scene 1, attribute 01

released: Scene 1, attribute 02

held for 10 seconds (LED indicator starts blinking): enter the setting menu >> 5 x tap up to change smart bulb mode (see parameter 11)

 

Lower Paddle: 

1 x tap: load off; Scene 2, attribute 00

2 x tap: Scene 2, attribute 03

3 x tap: enter exclusion (unpairing) mode; Scene 2, attribute 04

4 x tap: Scene 2, attribute 05

5 x tap: Scene 2, attribute 06

held: Scene 2, attribute 01

released: Scene 2, attribute 02

held for 10 seconds (LED indicator starts blinking): enter the setting menu >> 5 x tap down for factory reset; 2 x tap down to enable the range test tool.

 

Supported Command Classes:

COMMAND_CLASS_ZWAVEPLUS_INFO_V2,
COMMAND_CLASS_SWITCH_BINARY_V2,
COMMAND_CLASS_CONFIGURATION_V4,
COMMAND_CLASS_CENTRAL_SCENE_V3,
COMMAND_CLASS_ASSOCIATION_V3,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3,
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_VERSION_V3,
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1,
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1,
COMMAND_CLASS_INDICATOR_V3,
COMMAND_CLASS_POWERLEVEL_V1,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION_V1,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5

 

How to Access the Advanced Settings:

 

SmartThings

Hubitat

Vera

Home Assistant

 

All ZEN71 switches can be updated via OTA firmware updates, here is how to do that. After you register your product and create an account here, you can access all firmware files here. Questions? Feel free to reach out to our customer service, we're here 7 days a week!

Feedback
1 out of 3 found this helpful

Have you tried our virtual assistant chatbot? This AI tool can help you find answers from thousands of articles in our Knowledge Base quickly. Find it in the bottom righthand corner of the page.

Need more help? Our friendly team is ready to help you with any questions or concerns you may have about Zooz devices. Click here to submit a support ticket.

Are your devices registered? Extended warranty and firmware access is available for registered Zooz customers. Click here to submit your registration form.

Find the latest Zooz devices and great Z-Wave deals at The Smartest House.
 
scroll to top icon