Here is a full list of advanced settings (parameters) for the ZEN76 On/Off Switch:
Some parameters were added in later firmware updates so please make sure you're on the latest firmware to have all of the settings below available. You can view the change log for the ZEN76 here.
On/Off Paddle Orientation
Parameter 1: Choose if you want the upper paddle to turn the light on or turn the light off when tapped.
Values:
0 – Upper paddle turns the light on, lower paddle turns it off (default)
1 – Upper paddle turns the light off, lower paddle turns it on
2 – Any paddle turns light on/off
Size: 1 byte dec
LED Indicator Control
Parameter 2: Choose if you want the LED indicator to turn on when the switch (light) is on or off, or if you want it to remain on or off at all times.
Values:
0 – LED indicator is on when switch is off, LED indicator is off when switch is on (default)
1 – LED indicator is on when switch is on, LED indicator is off when switch is off
2 – LED indicator is always OFF
3 – LED indicator is always ON
NOTE: tap the upper paddle 6 times quickly to change this mode.
Size: 1 byte dec
Parameter 14: Choose the color of the LED indicator.
Values:
0 – white;
1 – blue (default)
2 – green
3 – red
Size: 1 byte dec
Parameter 15: Choose the LED indicator's brightness level.
Values:
0 – bright (100%)
1 – medium (60%) (default)
2 – low (30%)
Size: 1 byte dec
Parameter 18: Enable / disable LED indicator for setting changes. Choose if you want the LED indicators to flash whenever a parameter (settings) is adjusted on the device to confirm the change. Disable this feature if you're using the LED indicators in automations.
Values:
0 – LED indicators flash to confirm a setting change (default)
1 - LED indicators don't flash if a setting is changed
Size: 1 byte dec
Auto Turn-Off Timer
Parameter 3: Use this parameter to enable or disable the auto turn-off timer function (the time after which you want the switch to automatically turn off once it has been turned on).
Values:
0 – timer disabled (default)
1 – 65535 (minutes)
Size: 4 byte dec
Auto Turn-On Timer
Parameter 5: Use this parameter to enable or disable the auto turn-on timer function (the time after which you want the switch to automatically turn on once it has been turned off).
Values:
0 – timer disabled (default)
1 – 65535 (minutes)
Size: 4 byte dec
On Off Status After Power Failure
Parameter 8: Set the on off status for the switch after power failure.
Values:
0 – forced to OFF (regardless of state prior to power outage)
1 – forced to ON (regardless of state prior to power outage)
2 – remembers and restores on/off status after power failure (default)
Size: 1 byte dec
Enable/Disable Scene Control
Parameter 10: Enable or disable scene control functionality for quick double tap triggers.
Values:
0 – scene control disabled (default)
1 – scene control enabled
Size: 1 byte dec
Smart Bulb Mode: Enable/Disable Paddle / Z-Wave Control
Parameter 12: Enable or disable local on/off control. If enabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through paddles.
Values:
0 – physical paddle control disabled
1 – physical paddle control enabled (default)
2 – physical paddle and Z-Wave control disabled
NOTE: hold the lower paddle for 10 seconds until the LED indicator starts blinking, then within 2 seconds, tap the upper paddle 5 times quickly to change this mode. The LED indicator will stay solid green for 3 seconds to confirm the change.
FOR FIRMWARE 10.20, 2.20 AND 3.10 (800LR) (or higher): Hold the UPPER paddle for 10 seconds until the LED indicator starts blinking, then within 2 seconds, tap the upper paddle 5 times quickly to change this mode. The LED indicator will stay solid green for 3 seconds to confirm the change.
Size: 1 byte dec
Parameter 13: Set reporting behavior for disabled physical control.
Values:
0 – switch reports on/off status and change LED indicator state even if physical and Z-Wave control is disabled (default)
1 – switch doesn't report on/off status or change LED indicator state when physical (and Z-Wave) control is disabled
Size: 1 byte dec
Association Reports
Parameter 16: Choose how the switch reports its status back to the hub.
Values:
0 – binary switch report for Z-Wave control, basic set report for paddle control
1 – binary switch report for both Z-Wave and paddle control (default)
Size: 1 byte dec
Enable/Disable Programming on the Paddles
Parameter 17: Enable or disable programming functionality on the switch paddles. If this setting is disabled, then inclusion, exclusion, smart bulb mode no longer work when switch paddles are activated (factory reset and scene control will still work) - that means you can now use triple-tap triggers on the switch for scenes and remote control of other devices.
Values:
0 – programming enabled (default)
1 – programming disabled
Size: 1 byte dec
MANUAL CONTROL
Upper Paddle:
1 x tap: load on; Scene 1, attribute 00
2 x tap: Scene 1, attribute 03
3 x tap: enter inclusion (pairing) mode (only if the switch is not included to the hub); Scene 1, attribute 04
4 x tap: Scene 1, attribute 05
5 x tap: Scene 1, attribute 06
6 x tap: change LED indicator mode (see parameter 2)
held: Scene 1, attribute 01
released: Scene 1, attribute 02
held for 10 seconds (LED indicator starts blinking): enter the setting menu >> 5 x tap up to change smart bulb mode (see parameter 12)
Lower Paddle:
1 x tap: load off; Scene 2, attribute 00
2 x tap: Scene 2, attribute 03
3 x tap: enter exclusion (unpairing) mode; Scene 2, attribute 04
4 x tap: Scene 2, attribute 05
5 x tap: Scene 2, attribute 06
held: Scene 2, attribute 01
released: Scene 2, attribute 02
held for 10 seconds (LED indicator starts blinking): enter the setting menu >> 5 x tap down for factory reset; 2 x tap down to enable the range test tool.
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO_V2,
COMMAND_CLASS_SWITCH_BINARY_V2,
COMMAND_CLASS_CONFIGURATION_V4,
COMMAND_CLASS_CENTRAL_SCENE_V3,
COMMAND_CLASS_ASSOCIATION_V3,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3,
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_VERSION_V3,
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1,
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1,
COMMAND_CLASS_INDICATOR_V3,
COMMAND_CLASS_POWERLEVEL_V1,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION_V1,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
How to Access the Advanced Settings:
All ZEN76 switches can be updated via OTA firmware updates, here is how to do that. After you register your product and create an account here, you can access all firmware files here. Need help? Please reach out to our support team, we reply 7 days a week!