ZEN23 Toggle Switch Change Log

Here's where you'll find the changes and updates we made to the ZEN23 switch model so far.

VER. 1.0 (released 6/2016)

Original release.
Hardware:

  • Did NOT include neutral jumper or short screws for wall plate
  • Implemented the classic 3-way functionality with a dedicated add-on switch required (NO direct 3-way, do NOT connect to regular on/off switches)

Firmware: 20.16

  • No advanced settings available

VER. 1.01 (released 12/2016)

Firmware: 20.15

  • Added advanced setting for toggle control

VER. 2.0 (released 9/2017)

Hardware:

  • Added neutral jumper and short screws for wall plate
  • Added Direct 3-way solution (no add-on switch needed)

Firmware: 1.05

  • Added advanced settings for toggle control

VER. 3.0 (released 4/2019)

Hardware:

  • Updated back cover for easier installation (larger terminal holes)
  • Terminal screws arrive loose (unscrewed) for easier installation
  • Updated wall plate screw installation design (added more room for the screw to fit in easily)
  • Added foam to packaging

Firmware: 3.0

  • Added scene control (2 triggers only)
  • Changed association settings to send separate reports for manual and Z-Wave control
  • Added S2 security
  • Added OTA firmware updates
  • Added Built-in Timer
  • Added the ability to reset the switch to factory settings from the device directly
  • Added the ability to control load by toggling the toggle up or down
  • Added a setting to control status after power failure

VER. 3.01 (released 6/2019)

Firmware: 3.01

  • Added full scene control
  • Added the ability to disable local control

[VER. 3.02 UNPUBLISHED]

VER. 3.03 (released 9/2019)

Firmware: 3.03

  • Reduced manual control delay related to scene control functionality

VER. 3.04 (released 12/2019)

Firmware: 3.04

  • Added 3-way switch type setting to use momentary switches (like the ZAC99) in 3-way, 4-way, or 5-way set-ups without configuration limitations

VER. 3.05 (released as OTA 3/2020)

Firmware: 3.05

  • Added the ability to adjust reporting behavior for disabled physical control

If you have version 3.0 or higher, your switch can be upgraded via OTA firmware updates. Please request a firmware file here and include your order number for verification!