Here is a full list of advanced settings (parameters) for the ZSE41 XS Open | Close Sensor:
LED Indicator
Parameter 1: Turn the LED indicator for open/close status change on or off.
Values: 0 – LED indicator won’t blink when the sensor’s status is changed from open to close and vice versa; 1 – LED indicator will blink when the sensor’s open/close status is changed (default).
Size: 1 byte dec
Battery Reporting
Parameter 3: Set the threshold for battery reporting.
Values: 1-50 (%). Default: 10
Size: 1 byte dec
Parameter 4: Decide when the sensor should report low battery to the hub.
Values: 10-50 (% battery life). Default: 20
Size: 1 byte dec
Status Reporting
Parameter 5: Decide which status should the sensor report to the hub when the magnet touches the sensor.
Values: 0 – closed status reported when the magnet is by the sensor (default); 1 – open status reported when the magnet is by the sensor.
Size: 1 byte dec
Group 2 Association Commands
Parameter 6: Set the delay for the ON basic set command to be sent to the devices associated in Group 2 after the door is open.
Values: 0-3600 (seconds). Default: 0 (no delay).
Size: 4 byte dec
Parameter 7: Set the delay for the OFF basic set command to be sent to the devices associated in Group 2 after the door is closed.
Values: 0-3600 (seconds). Default: 0 (no delay).
Size: 4 byte dec
Remember to click the Z-Wave button 4 times quickly to wake the sensor up after updating the settings.
Your Open | Close Sensor can be updated via OTA firmware updates. You can access all firmware files here after you register your product and create an account here. Questions? Just reach out to our tech support team.