Here is a full list of advanced settings (parameters) for the ZSE18 Motion Sensor.
Motion Sensitivity
Parameter 12: Set motion sensitivity for the motion detector to minimize false alerts. Set value to 0 to disable motion reports.
Values: 0 -motion reports disabled; 1-8 where 1 indicates the lowest sensitivity and 8 indicates the highest sensitivity. Default: 4.
Size: 1 byte dec
Vibration Sensitivity
Parameter 13: Set vibration sensitivity for tamper alerts where 4 is the most sensitive and 1 is the least sensitive (only available in ZSE18 800LR).
Values: 1 – 4, where 4 is the most sensitive and 1 is the least sensitive. Default: 3
Size: 1 byte dec
Basic Set Reporting for Motion
Parameter 14: Enable or disable basic set reporting when motion is detected.
Values: 0 -Disable Basic Set Reports for motion; 1 -Enable Basic Set Reports for motion. Default: 0.
Size: 1 byte dec
Basic Set Reporting Value
Parameter 15: Select the basic set value to be sent when motion is detected.
Values: 0 – send 0xFF basic set report (ON) when motion is detected; 1 – send 0x00 basic set report (OFF) when motion is detected. Default: 0.
Size: 1 byte dec
Basic Set Reporting For Motion Cleared
Parameter 16: Enable or disable basic set reporting when motion is cleared.
Values: 0 – don’t send basic set reports when motion is cleared; 1 – send basic set reports when motion is cleared. Default: 0.
Size: 1 byte dec
Disable Vibration Reports
Parameter 17: Disable vibration reports for the sensor.
Values: 0 -Disable Vibration Reports; 1 -Enable Vibration Reports. Default: 1.
Size: 1 byte dec
Motion Clear Delay
Parameter 18: The amount of time the device waits to send a motion clear notification after the last motion event is detected.
Values: 10 - 65535, where 10 stands for 13 seconds and 65535 stands for 65538 seconds (add 3 seconds to each value number). Default: 30 seconds (value 27).
Values for ZSE18 800LR: 10 - 65535, where 10 stands for 10 seconds, 20 stands for 20 seconds, 30 stands for 30 seconds, etc. Default: 30 seconds (value 30)
Size: 2 byte dec
NOTE: Short clear time will increase activity and decrease battery life.
Enable Binary Sensor Reporting
Parameter 19: Enable or disable binary sensor reports when motion is detected.
Values: 0 -Disable Binary Sensor Reports for motion; 1 -Enable Binary Sensor for motion. Default: 0.
Size: 1 byte dec
LED Indicator
Parameter 20: Decide if you want the LED indicator to blink when motion is detected.
Values: 0 – LED doesn't blink when motion detected; 1 – LED blinks when motion detected. Default: 1
Size: 1 byte dec
TIP: Click the Z-Wave button 6 times quickly to change the LED indicator mode manually.
Low Battery Report
Parameter 32: Which % level should the device report low battery to the hub.
Values: 10 - 50 (%). Default: 10.
Size: 1 byte dec
Settings Lock
Parameter 254: Lock parameter settings (value 1) and prevent any values from being changed until unlocked again (value 0).
Values: 0 – Parameter settings unlocked; 1 – Parameter settings locked. Default: 0.
Size: 1 byte dec
How to Access the Advanced Settings
How to Access the Advanced Settings for the ZSE18 on Home Assistant
How to Access the Advanced Settings for the ZSE18 on HomeSeer
How to Access the Advanced Settings for the ZSE18 on Hubitat
How to Access the Advanced Settings for the ZSE18 on SmartThings
How to Access the Advanced Settings for the ZSE18 on Z-Box
Manual Wake-Up
Press and hold the Z-Wave button for 5 seconds to wake the sensor up after updating the settings so they can be immediately received and saved.
If you'd like to learn more how to use the advanced settings or where to adjust the parameters, just get in touch and our tech support team will guide you.
If you have any questions, please reach out to our support team. We're here to help you 7 days a week!